Forklift battery recharging

1, the pricing review Yugoslavia: the battery is intact, the wiring is intact, and open the cap. Do not open or cancel the battery on the plug injection liquid-liquid, charge or encumbrance before Do not add batteries, liquid, smoking is prohibited in the area, causing sparks or fire, can not simultaneously charging the Laptop battery discharge, recharge the battery will not hold the metal tools and charging Do not repair batteries, charging the electrolyte temperature is below 55

 

2, in the case of batteries, will be the proportion of the electrolyte and 1.26 cooled to 30 after cell injection, injection rate higher than the shield 10 ~ 20 mm for the good and wait 6 hours, the fluid temperature fell below 35 before charging begins. For the purposes of the electrolyte according to the proportion of refer to 30 at different temperatures should lead to the following formula: D30 Dt = 0.007 (T-30 )

 

3, charging the electrolyte temperature of not more than 55 , otherwise, should be taken to reduce the load current, artificial cooling or suspend the load and so on.

 

4, recharge the VGP-BPS13 battery of the saturation voltage and the proportion of electrolyte 2 to 3 hours does not rise substantially and issued a large number of bubbles, the proportion of electrolyte to 1.26, voltage of a single cell to 2.4V.

 

5 where the voltage of a single cell to 1.7 V, the voltage meter voltage of 41V (driving load), electrolysis has dropped to 1.18 should be loaded in a timely manner.

 

6, battery charge, when the end use of distilled water or dilute sulfuric acid accounted for 1.4, adjust the electrolyte density of 1.26 and maintain the proper height. Battery charging voltage of the electrolyte should be the proportion of start and stop recording. The records will contribute to the maintenance of the VGP-BPS10 battery and the safety analysis.

 

7, the batteries must not approach the heat source and heat source. Gas cover charge of the CAP is completed, wipes the electrolyte outside the Splash to keep the joints clean and dry, and coated with petroleum jelly. Batteries should be removed from the car wash outside.

 

8 Battery charging environment must be well ventilated. In particular, the pricing in the truck to be forced exhaust. Equipment loading the battery must be well ventilated rooms, the temperature is above 40 can calculate the movement of air to prevent accumulation of hydrogen gas when charging the battery - the explosion of gas oxygen mixture, you can use the following formula: Q = 0.05 × I × N (where Q = air flow, I: Charge the end of the current load, N: number of batteries monomer ) should ensure that the load is greater than the amount of airflow inside a formula to calculate the amount of airflow.

 

9, the beginning of battery charging data can often be referring to the instruction manual.