Solar energy communications base station lead-acid battery maintenance
Battery Group is the base station to achieve DC uninterruptible power supply is an important amount of their investment and power rack is approximately equal. When mobile base stations are used in the twentieth century developed VRLA batteries (VRLA batteries called). Due to the structure of the valve seal, and do not need to add the acid, add water to maintain non-acidic, avoid acid mist and equipment can be placed with the room. Because of their small size, light weight, self-discharge is low, less maintenance, long life, easy to use, safe and reliable, well received by users. But we must see that, first the basic electrochemical principle of this battery remains the same, and therefore the intrinsic characteristics of electricity requires not only has not changed, but called for more stringent, the share of others, the battery in the promotion of top manufacturers instructions may be more or fewer cells such as “maintenance free” batteries, caused part of maintenance personnel believe that the battery requires no maintenance because it is the impact of this misunderstanding. Thereby strengthening the scientific team of this maintenance and battery maintenance to improve their availability is still very important. Dell Latitude D810 battery Dell Latitude D820 battery
The first is to avoid overcharging. Batteries and battery life and performance of the accumulation of heat generated internally is closely linked to the main source of heat inside the battery to the electrochemical reaction of the internal power loss, you can simply look to voltage and load current product. In the new oxygen-reaction combination float current is increased, producing more heat at a constant voltage, the float current will increase as the temperature increases, causing a temperature rise further. Thermal runaway phenomenon is caused by VRLA how the structure of endemism. Thermal runaway often bring serious damage such as loss of battery water, shell ‘drum belly “, etc. In severe cases, the disposal of the battery. To avoid the extra cost of providing instructions in strict accordance with the manufacturers charge voltage values. Now, a combination of power can be adjusted and intelligent management, should be noted that the first is to set up correctly, followed by unauthorized persons generally can not be changed arbitrarily.
The second is to prevent charging enough. And overload on the contrary, the absence of load the tension load is mainly due to low or too low. Or a problem of system HSTNN-lB31 PB991A rack.
The third is to prevent excessive discharge. Depth of discharge and battery designed to charge and discharge cycles (life) are closely linked. For example, the depth of discharge of 5%, the cycle number is 10 000 times when the depth of discharge of 50%, the number of cycle is only 800 times. In severe cases, can cause excessive electrical discharges in the battery can no longer active in the best condition, or even abandoned. Different flow of time and termination of its discharge voltage is different, the release of the effective capacity is also different, and the temperature of the environment. This is not a longer list and plot the curve, the different specifications of the manufacturer of the battery is up to. Maintenance personnel should be concerned, and in strict conformity with the corresponding data set in the monitoring unit may not be changed by accident. Now power rack manufacturers have designed the battery under the civil power, which is when the battery runs down to adjust the termination voltage, monitoring controls, automatically cut off the discharge circuit the battery. More manufacturers are taking into account the monitoring unit for any reason (subject to the power of their work may BE) can not detect the battery voltage or may be issued a directive to stop when the other equipment have been forced to leave the circuit. Therefore, inspection of the maintenance staff should also be concerned about the reliability of circuit equipment, ensuring control and maintenance. VGP-BPS5 VGP-BPS9A
4 is to control the temperature. When the battery temperature, the electrolyte has intensified, the battery internal resistance decreases, the float current increases, leading to increased corrosion of conductive parts, the reduced life on the contrary, the weakening of activity in the electrolyte, the battery internal resistance to increase the burden of discharging the battery capacity to weaken. Therefore, the right to monitor the battery temperature and control temperature and maintaining it is very necessary. Must be accompanied by the charge voltage temperature compensation to prevent overload at high temperatures and low temperatures of less filling. The vast majority of the use of VRLA batteries in place, take the temperature controlled at 25 degrees, accelerated aging tests showed that the ambient temperature of 10 degrees without adjusting the charging voltage, its autonomy is reduced by half. PA3399U-2BRS PA3421U-1BRS
5 is the timely replacement of the defective battery. Since each process a single difference in the long term float could get little “late”, there will be regular monitoring of the unit is a rechargeable battery for management functions to activate the monomer in rear, so as not to further delay. But often in late May and eventually become defective battery. You can use several methods to determine if she was terminally ill, as the capacity of their separate trials, or on-line testing in the resistance and so on. The key is to quickly replace the defective battery, so the availability of battery life and the whole group is very important.
6 is the proposal on a regular basis to test the capacity of the battery and the discharge test. Capacity test is to undergo a medical examination of the A1008 battery, of course, an increased workload, but the needs and possibilities to consider, it is recommended to conduct sampling test conditions are needed.